| Home Search Quote Cross Order Online Catalog Reps Technical Terms Distributors About Us | |||||||||||||
|
|||||||||||||
| Material Selection | |||||||||||||
|
*Most
Cable Ties are ordered in Nylon 6/6- this is included in the part number. When ordering anything other than Nylon 6/6 please specify material. No need to specify material for Cable Tie Combo-Packs, Flexible Tubing & Tensioning Tools |
|||||||||||||
|
MATERIALS |
Cable Ties | Identification & Mounted Hole Ties | Releasable & Beaded Ties |
Combo Packs |
Mounting Bases |
Flexible Tubing |
Tensioning Tools | ||||||
|
Nylon 6/6 / Natural Many Colors Available See Chart Below |
X | X | X | X | X | ||||||||
|
Nylon 6/6 / Black UV Stabilized Black Color Only |
X | X | X | X | |||||||||
|
Nylon 6/6 / Black UV Stabilized / Heat Stabilized Black Color Only |
X | X | |||||||||||
|
HalarŪ
Fluoropolymer/ Distinctive Maroon Color |
X | ||||||||||||
|
TefzelŪ Fluoropolymer/
distinctive blue color |
X | ||||||||||||
|
Polyolefin Many Colors Available See Chart Below |
Flexible Tubing only available in Polyolefin |
X | |||||||||||
| Metal |
Three styles of tensioning tools available in metal |
X | |||||||||||
| Plastic |
One style of tensioning tool available in plastic |
X | |||||||||||
| Color Selection | |||||||||||||
|
Choose & write down your COLOR code-
Go Back to
|
|||||||||||||
|
COLORS |
Color Code |
Cable Ties |
Identification & Mounted Hole Ties |
Releasable Ties | Beaded Ties |
Combo Packs |
Mounting Bases |
Flexible Tubing |
|||||
| Natural | N | X | X | X | X | X | X | X | |||||
| Black | B | X | X | X | X | X | X | ||||||
| Brown | BN | X | X | ||||||||||
| Red | R | X | X | ||||||||||
| Orange | O | X | X | ||||||||||
| Yellow | Y | X | X | ||||||||||
| Green | G | X | X | ||||||||||
| Blue | BU | X | X | ||||||||||
| Purple | P | X | X | ||||||||||
| Gray | GY | X | X | ||||||||||
|
Fluorescent
Green |
FG | X | X | ||||||||||
|
Fluorescent
Pink |
FP | X | X | ||||||||||
|
Fluorescent
Yellow |
FY | X | X | ||||||||||
|
Fluorescent
Orange |
FO | X | X | ||||||||||
|
Fluorescent
Blue |
FB | X | X | ||||||||||
| Material Specifications | |||||||||||||
|
MATERIALS |
SPECIFICATIONS | ||||||||||||
|
Nylon 6/6 / Natural |
General purpose nylon 6/6 is suitable for use in most practical applications. Continuous temperature ranges up to 150°F. Nylon 6/6 is the most commonly used grade for cable tie production. Meets UL 94V-2 flammability rating. Working temperature range is from 40°F. to 185°F. |
||||||||||||
|
Nylon 6/6 / Black UV Stabilized |
UV Stabilized nylon 6/6 is used in continuous or constant exposure in outdoor use. This nylon cable tie is a weather resistant grade and enabling it to endure additional ultraviolet (UV) light. Stabilizers are incorporated in the nylon resin upon production. Only available in black. |
||||||||||||
|
Nylon 6/6 / Black UV Stabilized / Heat Stabilized |
UV / Heat Stabilized nylon 6/6 is used in continuous or constant exposure in high temperatures up to 250°F. General purpose nylon 6/6 will have a reduction in physical properties and fatigue as a result of high temperatures. Nylon cable ties that are specially formulated with heat stabilizers provide additional thermal endurance protection. Heat stabilized nylons are engineered for continuous exposure to temperatures ranging above 185°F. This nylon meets UL standards for electrical applications. Only available in black. |
||||||||||||
| HalarŪ |
HalarŪ performs similarly to TefzelŪ. It's primary characteristic is lower smoke density when burned. HalarŪ is very desirable in areas where smoke generation is a concern, especially when bundling wire in plenum spaces. |
||||||||||||
| TefzelŪ |
TefzelŪ is weaker than general purpose nylon 6/6 (about 37%). Tefzel is resistant to a wide range of chemicals including sulfuric acids and concentrated hydrofluoric acids. It is also a low water-absorbing material which has a minimal affect with moisture. Tefzel is radiation resistant up to 100 megarads and meets IEEE requirement 333. This material can also withstand high temperatures, ultraviolet light exposure, and meets UL flammability requirement 94V-0. |
||||||||||||
| Polyolefin |
Flexible polyolefin tubing is rated
for continuous operation from -55°C.
|
||||||||||||
| Material Properties | |||||||||||||
|
MATERIAL |
Continuous Operating Temperature |
Tensile Strength at 73°F. -Dry as Molded ASTM-D-638 (PSI) |
UL Flame Rating |
Oxygen Index % |
Gamma Radiation Resistance |
||||||||
| MAX. | MIN. | ||||||||||||
|
Nylon 6/6 / General Purpose |
185°F.
85°C. |
-40°F.
-40°C. |
12,000 | 94V- 2 | 28 | 1 X 1015 Rads | |||||||
| Nylon 6/6 / Heat Stabilized |
220°F.
105°C. |
-40°F.
-40°C. |
12,000 | 94V- 2 | 26 | 1 X 1015 Rads | |||||||
| Nylon 6/6 / UV Stabilized |
185°F.
85°C. |
-40°F.
-40°C. |
12,000 | 94V- 2 | NA | 1 X 1015 Rads | |||||||
| Nylon 6/6 / Heat Stabilized / UV Stabilized |
220°F.
105°C. |
-40°F.
-40°C. |
12,000 | 94V- 2 | 25 | 1 X 1015 Rads | |||||||
| TefzelŪ |
302°F.
150°C. |
-50°F.
-46°C. |
7,500 | 94V- 0 | 30 | 2 X 108 Rads | |||||||
| HalarŪ |
284°F.
140°C. |
-50°F.
-46°C. |
7,500 | 94V- 0 | 60 | 2 X 108 Rads | |||||||
| Cable Tie Tensioning Tools | |||||||||||||
|
Part Number |
Operating Range | ||||||||||||
| UN-100 | Fastens and automatically cut ties. / 18 lb. - 50 lb. ties / Extra Lightweight to Lightweight. | ||||||||||||
| UN-300 |
For cable tie thickness up to 2.3mm. / for cable tie width from 9.5mm /
single spring loaded and comfortable hand force/ fasten and automatic cut ties, with adjustable bundling pressure. /
120 lb. - 175 lb. ties / Heavy Duty to Extra Heavy Duty. |
||||||||||||
|
UN-400P (Plastic) |
For cable tie thickness up to 1.6mm. / for cable tie width from 2.2 to 4.8mm / fasten and automatic cut ties, with adjustable bundling pressure. / 18 lb. - 50 lb. ties / Extra Lightweight to Lightweight. | ||||||||||||
|
UN-400M (Metal) |
For cable tie thickness up to 1.6mm. / for cable tie width from 2.2 to 4.8mm / fasten and automatic cut ties, with adjustable bundling pressure. / 18 lb. - 50 lb. ties / Extra Lightweight to Lightweight. | ||||||||||||
| Heat Shrink Tubing Properties | |||||||||||||
|
Single- Wall Flexible Polyolefin Tubing |
|||||||||||||
|
Part |
Operating Temp. Range |
Shrink Temp. (min.) |
Shrink Ratio |
Standard Sizes Expanded Diameter |
Dielectric Strength (V-mil) |
Volume Resistivity (ohm-cm) |
Tensile Strength (PSI) |
||||||
| UNP- 221 Series |
- 55°C
to + 135°C |
212°F 100°C |
2:1 | 3/64" to 4" | 900 | 1015 | 2400 | ||||||
|
Material
|
Flexible Polyolefin - General Purpose flame retardant insulation for
UL, CSA and MIL-DTL-23053/5 applications; cable and component covering.
Class 1 = opaque colors; Class 2 = clear. |
||||||||||||
| Flexible Polyolefin Typical Properties | |||||||||||||
|
Applicable Specifications MIL- DTL - 23053/5, Class 1, 2; AMS-3636, AMS-3637; UL File E-39100; CSA LR38227; ABS |
|||||||||||||
| PHYSICAL | ELECTRICAL | CHEMICAL | |||||||||||
|
Tensile Strength |
2400 PSI |
Dielectric Strength |
900 V/mil |
Corrosive Effect | Non-Corrosive | ||||||||
| Ultimate Elongation | |||||||||||||